Babel Buster®... The BACnet Gateway Brand Everybody Remembers.

BACnet network gateways are used to connect non-BACnet devices to a BACnet network, or vice versa. The most commonly used BACnet gateway is used to connect Modbus devices to BACnet networks. A BACnet router is used to connect a BACnet MS/TP network to a BACnet IP network. Other types of routers exist, but MS/TP to IP is the most common BACnet router.

BACnet gateways from Control Solutions are lower cost and easier to use than our competition. There are no additional drivers or software to buy. Simply select the model that represents the functionality you require, and all software you need is included. Configuration software is included in the web user interface for some models. All other models have stand-alone configuration software you may download to your PC at no cost. Online user guides and videos are provided for most models to get you up and running as quickly as possible.

Convert BACnet MS/TP to Modbus RTU

BB2-3010 BACnet MS/TP to Modbus RTU Gateway

Babel Buster

BB2-3010

Babel Buster BB2-3010 is a fully configurable universal Modbus RTU to BACnet MS/TP gateway. The Babel Buster BB2-3010 is an RTU master used to make multiple Modbus RTU RS-485 devices accessible on a BACnet network. The BB2-3010 is also capable of acting as a BACnet MS/TP client and Modbus RTU slave, allowing BACnet devices to be connected to a Modbus network. The BB2-3010 can also be MS/TP slave and Modbus slave at the same time for putting industrial PLC's on a BACnet network.

Learn more...

Convert Modbus TCP to BACnet MS/TP

BB2-3060 Modbus TCP to BACnet MS/TP Gateway

Babel Buster

BB2-3060

Babel Buster BB2-3060 is a fully configurable universal Modbus TCP to BACnet MS/TP gateway. The Babel Buster BB2-3060 is a TCP client (master) used to make multiple Modbus TCP devices accessible on a BACnet network. The BB2-3060 is also capable of acting as a BACnet MS/TP client and Modbus TCP server (slave), allowing BACnet devices to be connected to a Modbus network. The BB2-3060 can also be MS/TP slave and Modbus slave at the same time for putting industrial PLC's on a BACnet network.

Learn more...

Convert BACnet IP to Modbus RTU and TCP, Convert BACnet IP to SNMP, Connect BACnet to WiFi Sensors.

BB2-7010 BACnet IP to Modbus RTU and TCP Gateway

Babel Buster

BB2-7010

Babel Buster BB2-7010 contains up to five different clients and four different servers. The BB2-7010-01 includes BACnet/IP client and server, Modbus TCP client and server (master and slave), and Modbus RTU master and slave. Modbus devices are accessible from BACnet IP and vice versa. The BB2-7010-02 and additional models also include an SNMP client and server (agent), making BACnet data accessible via SNMP or making SNMP devices accessible from BACnet. Additional models include support for collecting data from third party WiFi sensors and controlling WiFi actuators.

Learn more...

BACnet IP to MS/TP Router, Remap BACnet Objetcts, Convert BACnet to Modbus TCP, SNMP

BB2-7030 BACnet IP to MS/TP Router

Babel Buster

BB2-7030

Babel Buster BB2-7030 is a BACnet IP to MS/TP Router, configured or learning, that will route BACnet IP to MS/TP and vice versa via its local ports, and supports full router capability for multi-hop internetworks including via NAT WAN routers. The BB2-7030 is also a client/server gateway that allows remapping BACnet objects from multiple slaves into one master. The gateway also features support for Modbus TCP or SNMP to MS/TP, includes BBMD support, and includes proxy support.

Learn more...


Convert BACnet MS/TP to LonWorks

BB2-3020-NB BACnet MS/TP to LonWorks Gateway

Babel Buster

BB2-3020-NB

Babel Buster BB2-3020-NB is a BACnet MS/TP slave (server) device that functions as a LonWorks device manager. NV Structures may be parsed to multiple BACnet objects when reading. Multiple BACnet objects may be packed into a single structured variable when writing. All standard SNVT’s are supported. Objects mapped to Network Variable Outputs (NVO) will poll their assigned variable at the interval you specify. Network Variable Inputs (NVI) are written each time the mapped BACnet object is written.

Learn more...

Convert BACnet IP to LonWorks

BB2-7020-NB BACnet IP to LonWork Gateway

Babel Buster

BB2-7020-NB

Babel Buster BB2-7020-NB is a BACnet IP slave (server) device that functions as a LonWorks device manager. NV Structures may be parsed to multiple BACnet objects when reading. Multiple BACnet objects may be packed into a single structured variable when writing. All standard SNVT’s are supported. Objects mapped to Network Variable Outputs (NVO) will poll their assigned variable at the interval you specify. Network Variable Inputs (NVI) are written each time the mapped BACnet object is written.

Learn more...

Connect BACnet IP to Proprietary Serial ASCII

Babel Buster SP Custom BACnet IP to Proprietary Serial Gateway

Babel Buster

BBSP-Custom

Babel Buster SP Custom lets you create your own gateway. Designed to interface devices with a proprietary RS-232 ASCII protocol, the proprietary part of the protocol is user programmed using the built-in Script Basic. Simple function calls are provided to move data between your Basic program and BACnet IP objects. The BACnet IP side of this gateway is the same as our other BACnet IP gateways, and is configured via the internal web server.